Since 1993 we have manufactured nine types of thermocouple assemblies and RTD assemblies: B, R, S, K, E, J, T, N and Pt100, which meet the requirements of IEC standards.Measured temperature range is -40 to 1600℃, according to the use temperature, choose the wire diameter form Φ0.3mm to Φ3.2mm .

◆ Thermocouple assemblies and RTD assemblies

 

    Industrial assembly thermocouple is used to measure the temperature of the sensor, it can directly measure the 0-1600 range the various production process liquid, steam, gas medium and solid surface temperature. The foundation of national regulations, my factory finished in accordance with IEC international standard indexing number T, J, E, K, N, S, B type thermocouple.

 

□Technical indicators

 

Name

Type

Range(℃)

Diameter mm

Grade

Tolerance

Ni Cr-Ni Si

K

-40~1200

0.3~3.2

±1.5℃ or±0.4%t

Ni Cr Si-Ni Si Mg

N

-40~1200

Ni Cr-Cu Ni

E

-40~750

±2.5℃ or ±0.75%t

Fe- Cu Ni

J

-40~600

Cu- Cu Ni

T

-40~350

0.2~1.6

±0.5℃ or ±0.4%t

±1℃ or ±0.75%t

Pt Rh10-Pt

S

0~1400

0.5

±1℃ or ±[1+0.003(t-1100)]℃

Pt Rh 13- Pt

R

0~1400

±1.5℃ or ±0.25%t

Pt Rh 30- Pt Rh6

B

600~1600

0.5

±0.25%t

±4℃ or±0.5%t

 

□ Shape structure

 

 

Termination

Sketch

Process connection

  Code

Name

  Name

 Code

RTD

or

base

metal TC

3

Connection

head

     

    Non

1

6

Round

connector

Fixed

thread

2

7

Rectangle

connector

Adjustable

flange

3

3

Connection

head

Fixed

flang

4

Fixed

thread,

Tapered

protection

tube

6

Base

metal

TC

3

Connection

head

Right

angle

5

Noble

metal

TC

3

Connection

head

Non

1

 

□ Assembly type thermocouple (K-type) response time:

 

Wire OD

(mm)

Protection tube

τ0.632

Temperature step

Test condition

material

Dimension (mm)

3.2

SUS304

OD22

6min55s

Rm.temp.→600

In gas furnace

ID16

2min52s

600→Rm.temp.

Still water

1.6

SUS304

OD15

3min32s

Rm.temp.→600

In gas furnace

ID11

40s

1000→Rm.temp.

Still water

1.0

SUS304

OD12

1min14s

Rm.temp.→950

In gas furnace

ID8

2min28s

950→Rm.temp.

Cool in air

3.2

Without protection tube

49s

Rm.temp.→950

In gas furnace

1min32s

900→Rm.temp.

Cool in air

1.6

Without protection tube

27s

Rm.temp.→900

In gas furnace

52s

900→Rm.temp.

Cool in air

 

The more information and model selection please download my company's product samples for inspection